how to calculate dosing pump capacity

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • How do you calculate Boiler HP dosing system capacity

    2020-7-21 · How do you calculate Boiler HP dosing system capacity ... Now we have to choose a pump for dosing TSP . There for Total solution of TSP to be dosed in Boiler water at 15 LPH @ 50% stroke (Standard dosing required is 12-15 LPH for 100 TPH boiler) ... Boiler Feed Pumps Design factors & Pump Capacity calculation. at July 21, 2020.

    Get Price
  • Dosing Pump - an overview | ScienceDirect Topics

    In Electrical Systems and Equipment (Third Edition), 1992. 6.3.6 Dosing pump controls. The scheme shown in Fig 10.18 has four 415 V three-phase 50 Hz dosing pumps, each capable of delivering one-third of the maximum dosing rate.A ‘three out of four’ duty selection scheme is provided; the fourth pump is on standby and starts automatically upon failure of one of the duty …

    Get Price
  • Chemical Dosing Guidance - Avista Technologies

    2008-2-25 · accurately calculate the required level of ... Dosing Pump The dosing pumps should be sized to allow the specified dose at between 40 - 80% of the capacity of the pump. This will allow Chemical Tank Dosing Pump Calibration Tub e Isolation Valves Main Pipeline. TS13 –Chemical Dosing

    Get Price
  • CHEMICALS DOSING PUMPS CALIBRATION BASICS

    2021-4-14 · pump usually runs at. Use this formula to calculate the capacity at this setting: (Pump capacity, gph x Pump speed, % x Pump stroke, %) Example: (1, gph x 50% x 50%) = (1 x 0.5 x 0.5) = 0.25 gph Calibration Procedure Calculate thecapacity of pump atspeed and stroke rate which test will be run. 1.

    Get Price
  • Dosing pumps - Pump Supplier Bedu

    The dosing pumps are used for dosing thin liquids including chemicals. There are two types of dosing pumps including piston pumps and diaphragm pumps. The capacity can be controlled by the length of stroke with calibration from 0 to 100%. There is also the option of being able to set the speed of the electric motors by using a frequency control.

    Get Price
  • What is the formula to calculate pump capacity and

    2013-2-21 · For fire fighting system in high rise building we require 2 pumps 1) Jockey pump & 2) Main Pump to maintain pressure in risers. Please guide me and let me know the formula to calculate the capacity and LPM required for it. This is my request beside this if you can suggest some books for it.

    Get Price
  • Pump calculations - The Engineering Mindset

    2017-10-17 · Pump capacity measuring apparatus, including a pressure gauge, flow meter, and regulating valve. Measuring Pump Capacity for Irrigation System Design 3 3. Operate the pump to remove air from the pump and pipelines and to reach normal operating conditions. 4. Slowly close the regulating valve and measure the shut-off

    Get Price
  • Measuring Pump Capacity for Irrigation System Design

    Chlorine Metering Pump Sizing Calculator. Gallons (or liters) per minute at point of chlorine injection: Gallons Liters: Parts Per Million of Applied Chlorine Dosage: ppm (from 0.2 to 200ppm) Concentration of bleach you will be using: % (from 1% to 12.5%)

    Get Price
  • CHEMICALS DOSING PUMPS CALIBRATION BASICS

    2021-4-14 · Use this formula to calculate the capacity at this setting: (Pump capacity, gph x Pump speed, % x Pump stroke, %) Example: (1, gph x 50% x 50%) = (1 x 0.5 x 0.5) = 0.25 gph Calibration Procedure Calculate thecapacity of pump atspeed and stroke rate which test will be run. 1. Fill the calibration cylinder with the product that the pump is ...

    Get Price
  • Pump Calculator Spreadsheet | ITACA

    This spreadsheet allows the user to find the pump power requirement (Watts or Brake Horse Power) for various feeder pipe diameters (in) and given a known flow rate (LPS), pipe length (m) and head (m) and then select a suitable pump based upon available pump characteristic data.

    Get Price
  • Chlorine Metering Pump Sizing Calculator - Clean

    Chlorine Metering Pump Sizing Calculator. Gallons (or liters) per minute at point of chlorine injection: Gallons Liters: Parts Per Million of Applied Chlorine Dosage: ppm (from 0.2 to 200ppm) Concentration of bleach you will be using: % (from 1% to 12.5%)

    Get Price
  • Calculation: Diameter of the suction line at a dosing

    Vapour pressure of dosing agent at valve inlet temperature [bar] (Water at 20 °C = 0.023) H Saug: Pump suction height [m] (>0 at feed, <0 at suction) Density: Chemical density [kg/dm 3] (Water = 1.0) Q: Pump delivery capacity [l/h] F: Pump stroke frequency [stroke/min] L: Length of suction line [m] decimal places: NPSH a: Net Positive Suction ...

    Get Price
  • Pump Power Calculator - Engineering ToolBox

    2021-5-7 · Hydraulic Pump Power. The ideal hydraulic power to drive a pump depends on. the mass flow rate the; liquid density; the differential height - either it is the static lift from one height to an other or the total head loss component of the system - and can be calculated like. P h(kW) = q ρ g h (3.6 10 6) = q p (3.6 10 6) (1) where

    Get Price
  • Back to Basics Pump Sizing - AIChE

    2016-12-2 · In a positive-displacement (PD) pump, a discrete amount of fluid is trapped, forced through the pump, and discharged. A gear pump is an example of a PD pump (Figure 2). This pumping principle produces a pulsating flow, rather than a smooth flow. Its output flow tends to vary little with respect to the pressure at the pump outlet, because the moving

    Get Price
  • Pump flow rate calculation-ZB pump - zoompumps.com

    2019-6-19 · What is the pump flow rate calculation formula? In the process of using the pump, it is often necessary to calculate the pump flow, but many people do not know the pump flow calculation formula. We will take the submersible pump and gear pump as an example to introduce the pump …

    Get Price
  • Calculation Tools | Astralpool

    VICTORIA PLUS SILENT VS Calculator. The following application makes it possible to calculate the annual savings made by installing a VICTORIA variable speed pump in comparison with conventional single speed pumps found on the market.

    Get Price
  • Manual for the Design of Pipe Systems and Pumps

    2021-4-14 · The first step on the way to the optimal pump is the selection between a centrifugal pump or a positive displacement pump. The difference lies on one hand in the prin-ciple of transpor-ting the liquid and on the other hand in the pumping characteristic. There are two types of centrifugal pumps: 'non-self priming' and 'selfpriming'.

    Get Price
  • Chlorine Metering Pump Sizing - Residential Well

    2021-5-13 · Household Bleach is 5 1/4% Sodium Hypochlorite Liquid Pool Chlorine is 12 1/2% Sodium Hypochlorite Please Note: Our calculator will give you a good starting point, but once you turn on the chlorinator, be sure to actually measure the chlorine residuals downstream of the injection point. Other factors such as temperature, pH, and/or the type … Continue reading Chlorine Metering Pump Sizing

    Get Price
  • Pump Calculator Spreadsheet | ITACA

    This spreadsheet allows the user to find the pump power requirement (Watts or Brake Horse Power) for various feeder pipe diameters (in) and given a known flow rate (LPS), pipe length (m) and head (m) and then select a suitable pump based upon available pump characteristic data.

    Get Price
  • Pump Sizing Calculation

    2019-7-28 · Pump Sizing does the hydraulic calculation for a centrifugal pump and estimates differential head, hydraulic power, motor power, NPSH available.

    Get Price
  • Water Treatment Products Limited Equipment - Dosage

    2016-3-3 · Thus a Turn Down Ratio of 100 means that the pump is capable of dosing down to 1/100th of its maximum output. Therefore a pump rated at 5 litres/hour will obviously be suitable to dose 5 litres/hour, but – it will also be able to accurately dose down to 5/100 litres/hour, .05 litres/hour or 50 ml/hour.

    Get Price
  • Back to Basics Pump Sizing - AIChE

    2016-12-2 · In a positive-displacement (PD) pump, a discrete amount of fluid is trapped, forced through the pump, and discharged. A gear pump is an example of a PD pump (Figure 2). This pumping principle produces a pulsating flow, rather than a smooth flow. Its output flow tends to vary little with respect to the pressure at the pump outlet, because the moving

    Get Price
  • Ground Drive Metering Pumps Calculator - John Blue

    Calculate Flow Rates and Pump Settings for Your John Blue Metering Pump. John Blue’s Ground Drive Metering Pumps Calculator calculates ground-driven piston pump and squeeze tube pump settings, application rates, and other metering pump flow parameters. The calculator works in both standard and metric units.

    Get Price
  • Pump Performance | Control the flow with metering

    2011-11-3 · The capacity in the original metering pump was changed by adjusting the stroke length of the piston from outside the pump. Figure 4 shows the same concept, but its stroke length adjustment via an internal, oil-bathed gear system is a technology introduced about 30 years after the first metering pump.

    Get Price
  • Chlorine Metering Pump Sizing - Residential Well

    2021-5-13 · Household Bleach is 5 1/4% Sodium Hypochlorite Liquid Pool Chlorine is 12 1/2% Sodium Hypochlorite Please Note: Our calculator will give you a good starting point, but once you turn on the chlorinator, be sure to actually measure the chlorine residuals downstream of the injection point. Other factors such as temperature, pH, and/or the type … Continue reading Chlorine Metering Pump Sizing

    Get Price
  • Wastewater Design Guidelines - 2013

    2017-7-29 · 2. A standby pump unit (internal) 3. A stationary auxiliary power source connected to a separate power feed substation or stationary generator 4. A pump-around connection coupling facility AND (a) For Pumping Capacity (Qp) ≤ 150 gallons per minute (gpm), or serving Equivalent Dwelling Units (EDU) ≤ 200, no additional measure is required.

    Get Price
  • Filter Press Sizing Calculations | Automatic Filter Press ...

    2021-5-13 · Filter Press Sizing Calculations The attached graphs and data sheets are for your use in estimating filter press sizing and chemical dosing requirements. All calculations used in preparing this material are based on the following: Cake dry solids: 30% by weight Cake density: 75#/ft³ Ferric chloride dose: 5% by weight Ferric […]

    Get Price
  • Cooling Tower Basic Calculations - Yamatho Supply LLC

    2017-2-28 · Holding Capacity or System Volume : The holding capacity of a system is the amount of water in the system expressed in gallons (cubic meters). Normally most of the capacity of a system is contained in the cooling tower basin; the exact amount, however, can be determined only by conducting a TRASAR diagnosis or an ion concentration study. This ...

    Get Price
  • chemical dosing guidance - Avista Technologies

    2009-4-24 · Dosing Pump The dosing pumps should be sized to allow the specified dose at between 40 - 80% of the capacity of the pump. This will allow the dose rate to be increased should the water quality change, and it is necessary to change the dose rate. Chemical Tank Dosing Pump Calibration Tube Isolation Valves Main Pipeline

    Get Price
  • Pump Sizing and Selection Made Easy - Chemical

    2018-1-1 · In Equation (16), N (rpm) is the actual pump rotating speed, Q (gal/min) is the pumping capacity, and H (ft) is the total head at the best efficiency point, corresponding to speed N and capacity Q. Suction specific speed ( N s , rpm) values — obtained by substituting NPSH a for H — of less than 8,500 rpm are typical for commercially ...

    Get Price
  • Tips for Using Pulsation Dampeners in Dosing or

    2015-4-3 · The pump is a single-piston type, and its capacity per stroke is 30 cc. Equation 1 can be used to calculate the necessary volume of a pulsation dampener. P 2 x V 2 = P 0 x V 0 Equation 1. Where: P 2 = maximum pressure value accepted in the circuit V 2 = final gas volume P 0 = inflating gas pressure of the dampener V 0 = volume of the dampener ...

    Get Price
  • Metering Pump Principles | Milton Roy

    The metering pump is a positive displacement chemical dosing device with the ability to vary capacity manually or automatically as process conditions require. It features a high level of repetitive accuracy and is capable of pumping a wide range of chemicals including acids, bases, corrosives or …

    Get Price
  • Progressing Cavity Pump Guide and Design

    2020-1-27 · High Accuracy – Due to flow being directly proportional to pump speed, and due to its cavity design, it enables flows to be very predictable enabling it to be used in metering and dosing applications High Flows – Flows of up to 600M³H can be achieved due to rotary positive displacement design which is second only to large screw pumps High ...

    Get Price
  • DETERMINATION OF CLOSED SYSTEM VOLUME

    2008-5-16 · circulating pump capacity by 3. For example, for a circulating pump capacity of 150 USG/min, the estimated total system volume would be 150 X 3 = 450 USG. Although the estimated volume is determined very quickly with this method, it should be considered to be only a …

    Get Price
  • Plunger Pump Flow Calculator | Piston Pump Flow

    Note: This Plunger Pump Flow Calculator assumes 100% volumetric efficiency, meaning it does not consider any slip or back flow of fluid through the valves of the pumps, and assumes that there is no leakage through the packing or any other part of the fluid chamber. If more in depth calculations are needed to calculate the volumetric efficiency of a plunger pump, contact the Power Zone ...

    Get Price
  • HOW TO design a pump system

    2019-2-21 · What is friction in a pump system. Friction is always present, even in fluids, it is the force that resists the movement of objects. Figure 7. When you move a solid on a hard surface, there is friction between the object and the surface. If you put wheels on it, there will be less friction. In the case of moving fluids such as water, there is ...

    Get Price
  • Basic Water Treatment Math Formulas for Surface and

    2018-6-19 · Revised 9/15 Basic Water Treatment Math Formulas for Surface and Well Exams These formulas are intended to serve as a general resource and …

    Get Price
  • Peristaltic Pump Flow Rate Calculation? - ResearchGate

    I am trying to predict the flow rate of my peristaltic pump. I have 1.0 mm ID tubing, 10 rollers, and the diameter of the rotating portion is 30 mm.

    Get Price
  • Pumps, Sizing, Dosing & Flow Pump Choice & Settings

    2017-1-6 · Pump Choice & Settings Pumps, Sizing, Dosing & Flow Measurement Pump choices Purpose Pump sizing Operating point Dose Volume Demand Dosing Time Dosing Is there a pump? Pump Types Type of pump: Multi-stage Single-stage Grinder Pumps Some systems will have grinder pumps These macerate solids Need more power to grind material: 230V+

    Get Price
  • chemical dosing guidance - Avista Technologies

    2009-4-24 · Dosing Pump The dosing pumps should be sized to allow the specified dose at between 40 - 80% of the capacity of the pump. This will allow the dose rate to be increased should the water quality change, and it is necessary to change the dose rate. Chemical Tank Dosing Pump Calibration Tube Isolation Valves Main Pipeline

    Get Price
  • Pump Tank Sizing - Draft - University of Arizona

    2019-5-15 · Calculate Volume to Cover Pump (The inlet of the pump must be at least 4-inches from the bottom of the pump tank & 3 inches of water covering the pump is recommended) DOSING VOLUME 1 0.045 0.25 0.661 5,000-9,999 601-4,999 4 3 0.380 0.170 1.25 0.078 12 in/ft TANK CAPACITY Liquid Per Foot (Gallons) 500 or Alternating Dual Pumps Design Flow ...

    Get Price
  • Pump Sizing and Selection Made Easy - Chemical

    2018-1-1 · In Equation (16), N (rpm) is the actual pump rotating speed, Q (gal/min) is the pumping capacity, and H (ft) is the total head at the best efficiency point, corresponding to speed N and capacity Q. Suction specific speed ( N s , rpm) values — obtained by substituting NPSH a for H — of less than 8,500 rpm are typical for commercially ...

    Get Price
  • SECTION 9 Pumping Systems - University of Minnesota

    2016-1-19 · The pump capacity for these applications should be between 15-45 gpm. Using the pump curve and rise in elevation can allow for proper selection. Figure 9.3 Drop Box with inlet Pressure Displacement Figure 9.4 typical Drop Box Pumping in Pressure Systems There exists a third situation in which the pump is used to pump septic tank effluent to

    Get Price
  • How to calculate Anti-Scalant Feed Dosage?

    Therefore, your dosage should be set at the dosing pump to 3.45 ml/min for this particular example. Pump Settings. After diluting scale inhibitor solution (if required), it is necessary to set the feed pumping rate. This is done by adjusting the stroke length and/or stroke frequency (speed) knobs located on the chemical feed pump face.

    Get Price
  • Basic Water Treatment Math Formulas for Surface and

    2018-6-19 · Revised 9/15 Basic Water Treatment Math Formulas for Surface and Well Exams These formulas are intended to serve as a general resource and …

    Get Price
  • DETERMINATION OF CLOSED SYSTEM VOLUME

    2008-5-16 · circulating pump capacity by 3. For example, for a circulating pump capacity of 150 USG/min, the estimated total system volume would be 150 X 3 = 450 USG. Although the estimated volume is determined very quickly with this method, it should be considered to be only a …

    Get Price
  • HOW TO design a pump system

    2019-2-21 · What is friction in a pump system. Friction is always present, even in fluids, it is the force that resists the movement of objects. Figure 7. When you move a solid on a hard surface, there is friction between the object and the surface. If you put wheels on it, there will be less friction. In the case of moving fluids such as water, there is ...

    Get Price
  • Peristaltic Pump Flow Rate Calculation? - ResearchGate

    I am trying to predict the flow rate of my peristaltic pump. I have 1.0 mm ID tubing, 10 rollers, and the diameter of the rotating portion is 30 mm.

    Get Price