pump definition fire

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • The Anatomy of a Fire Pump | Fire Apparatus

    2011-6-1 · Annual pump testing provides the necessary data to determine continued fire pump capability. The Pump Body. The pump body is the part of the fire pump that controls and directs the flow of water from the inlet side through to the discharge. Within the pump body are three main parts: the intake section, the volute section, and the discharge section.

    Get Price
  • Fire Pump Sizing and Selection - PHCP Pros

    2014-3-14 · When starting a fire pump design, the most important item to consider is the water supply. If you are utilizing the city water supply as the primary source for the pump, you need to make sure that an accurate city water test is used. ... Refer to NFPA 13 for a more thorough definition of the classifications. Once the hazards have been ...

    Get Price
  • Regulations on Emergency Fire Pump - Marine Engineering

    2015-10-31 · What is emergency fire pump ? It is a fixed emergency fire pump independently driven by self cooled compression ignition engine or an electric motor which power is supply from emergency generator. When all the fire pumps are out of action either by disabling the pumps or their source of power, emergency fire pump can still be used. Where emergency fire pump is …

    Get Price
  • Fire Pumps and Systems for Firefighting Applications - RP ...

    2021-5-16 · Fire Pump House. Our packaged fire systems can be contained on a weather-proof, non-combustible enclosure engineered and constructed per NFPA-20 for a trouble-free and quick installation. Pressure from 40 to 519 + PSI. Flow from 150 to 5000 GPM. Drive Electric or Diesel.

    Get Price
  • Pump: Definition, Types, Advantages, Disadvantages ...

    2021-5-6 · Pump Definition: A pump is a device that is used for lifting the liquid from ground sources to the upper top surface or from one place to another place. Pumps are operated by the mechanism that is rotary, reciprocating and it consumes energy while performing mechanical work which is moving fluid from one place to another.

    Get Price
  • Fire Pumping Calculations: Every Pump Operator's Basic ...

    2012-10-1 · By definition, a fire stream is a stream of water after it leaves the nozzle until it reaches its final destination, which is usually the seat of the fire. ... Warren E. Fire Service Pump Operator ...

    Get Price
  • Pressure Maintenance (Jockey) Pumps | Fire Protection ...

    2) The jockey pump start point should be at least 10 psi (0.68 bar) less than the jockey pump stop point. 3) The fire pump start point should be 5 psi (0.34 bar) less than the jockey pump start point. When additional fire pumps are installed in series, use 10 psi (0.68 bar) increments for each additional pump.

    Get Price
  • Every Pump Operator’s Basic Equation

    2020-12-11 · when operating the fire pump. today, many pump pan-els have flow meters that allow the pump operator to match the readout on the pump panel with the gallon-per-minute ... By definition, a fire stream is a stream of water after it leaves the nozzle until it reaches its final destina-tion, which is usually the seat of the fire. as the streams are ...

    Get Price
  • PRESSURE SETTINGS FOR FIRE PUMP CONTROLLERS |

    1992-5-1 · PRESSURE SETTINGS FOR FIRE PUMP CONTROLLERS. Selecting the pressure points for pump cut-in and cut-out is dependdent on the features of each individual pump assembly or system. Factors influencing ...

    Get Price
  • Urban Dictionary: Johnny pump

    2021-3-5 · New York City fire hydrants were first installed in 1808, and by 1817 flip lid-style hydrants began to appear on street corners. The term 'johnny pump' is a nickname for fire hydrants that originated in Lower Manhattan and Brooklyn vernacular.

    Get Price
  • Manual fire pump | Article about manual fire pump by The ...

    How many of us Brummies can recall that in 1970 a team of 12 firemen from the Birmingham Fire Brigade set a world handpumping record by continuously operating an old-style manual fire pump for a period of 245 hours - gaining entry into the Guiness Book of Records?

    Get Price
  • Centrifugal Fire Pump Principles of Operation, Inspection ...

    2014-4-21 · Centrifugal Fire Pump Principles of Operation, Inspection Tests and Troubleshooting Guide. F–1031, Section 1000 Revised: 11/21/96 Page 1 of 7 Principles of Operation The two main parts of centrifugal pumps are the impeller(s) and volute(s). The impeller is powered to rotate within the volute, creating centrifugal force which hurls

    Get Price
  • Fire Pump Sizing and Selection - PHCP Pros

    2014-3-14 · When starting a fire pump design, the most important item to consider is the water supply. If you are utilizing the city water supply as the primary source for the pump, you need to make sure that an accurate city water test is used. ... Refer to NFPA 13 for a more thorough definition of the classifications. Once the hazards have been ...

    Get Price
  • Regulations on Emergency Fire Pump - Marine Engineering

    2015-10-31 · What is emergency fire pump ? It is a fixed emergency fire pump independently driven by self cooled compression ignition engine or an electric motor which power is supply from emergency generator. When all the fire pumps are out of action either by disabling the pumps or their source of power, emergency fire pump can still be used. Where emergency fire pump is …

    Get Price
  • Fire Pumping Calculations: Every Pump Operator's Basic ...

    2012-10-1 · By definition, a fire stream is a stream of water after it leaves the nozzle until it reaches its final destination, which is usually the seat of the fire. ... Warren E. Fire Service Pump Operator ...

    Get Price
  • Fire Pump Priming Basics - Part 1 | Firehouse

    2007-2-28 · Home; Apparatus; Fire Pump Priming Basics - Part 1. Dominic Colletti discusses fire pump accessories: they may not be glamorous, but priming systems are critical to pump …

    Get Price
  • Fire Pump Connections - Schneider Electric

    2019-7-14 · Fire Pump Connections 2700DB0201 Data Bulletin May 2002 3 Figure 1: Fire Pump Installation Fire pump disconnect To fire pump controller Main Incoming service Balance of board (not intended to show how the switchboard is actually constructed) Tap in separate section Electrical equipment should be serviced only by qualified personnel. No

    Get Price
  • Piping arrangements for fire pumps - Specifying Engineer

    2015-3-16 · Every fire pump installation needs to be provided with a testing means to ensure proper operation.At a minimum, arrangements must be provided to evaluate the pump at its rated condition as well as at its overload (150% of its rated capacity) condition. The means of testing must allow for the flow and discharge of significant quantities of water.

    Get Price
  • Urban Dictionary: Johnny pump

    2021-3-5 · New York City fire hydrants were first installed in 1808, and by 1817 flip lid-style hydrants began to appear on street corners. The term 'johnny pump' is a nickname for fire hydrants that originated in Lower Manhattan and Brooklyn vernacular.

    Get Price
  • Single-Stage Vs Two-Stage Water Pumps | Fire Apparatus

    2010-5-1 · This will cause the water in the fire pump to heat up. If the water gets too hot, a catastrophic pump failure is imminent. Finally, while single-stage pumps are designed to flow large volumes of water, they are not designed to produce high pressures. In fact, to develop 125 gpm at 200 psi (a typical 300-foot 1-1/2-inch attack line), a single ...

    Get Price
  • Pump: Definition, Types, Advantages, Disadvantages ...

    2021-5-6 · Pump Definition: A pump is a device that is used for lifting the liquid from ground sources to the upper top surface or from one place to another place. Pumps are operated by the mechanism that is rotary, reciprocating and it consumes energy while performing mechanical work which is moving fluid from one place to another.

    Get Price
  • Fire Pump Sizing and Selection - PHCP Pros

    2014-3-14 · When starting a fire pump design, the most important item to consider is the water supply. If you are utilizing the city water supply as the primary source for the pump, you need to make sure that an accurate city water test is used. ... Refer to NFPA 13 for a more thorough definition of the classifications. Once the hazards have been ...

    Get Price
  • Regulations on Emergency Fire Pump - Marine Engineering

    2015-10-31 · What is emergency fire pump ? It is a fixed emergency fire pump independently driven by self cooled compression ignition engine or an electric motor which power is supply from emergency generator. When all the fire pumps are out of action either by disabling the pumps or their source of power, emergency fire pump can still be used. Where emergency fire pump is …

    Get Price
  • Fire Pumps Manufacturers | Fire Pumps | SPP Pumps

    Fire Pump Manufacturers Total Fire Protection with Precision Engineering. Fire pumps are part of an applications water supply and are powered by electricity, diesel or steam. They activate when the pressure in the fire sprinkler systems falls beneath a certain level and provide water flow at a very high pressure to the sprinkler system, which ...

    Get Price
  • Different Types of Pumps: Working & Their Applications

    Fire Hydrant Systems. Fire hydrant pump systems are also named as hydrant boosters, fire pumps, & fire water pumps. These are high force water pumps intended to enhance the capacity of fire fighting of construction by increasing the force within the hydrant service as mains is not sufficient. The applications of this system mainly include ...

    Get Price
  • Positive Displacement vs. Centrifugal Fire Pumps | 2003-09

    2003-9-2 · Editor's Note: The pump curves referenced in this article could not be reproduced online. Please see the print edition for this information. Positive displacement pumps have been used in fire protection for many years. In fact, they were the first pump type to be utilized for mobile fire truck applications, long before centrifugal pump designs were used for pumping fire water.

    Get Price
  • Pump Terms and Definitions

    Classification by Specific Speed. Specific Speed (n s) - Specific speed is an index of pump performance at the pump's best efficiency point (BEP) rate of flow, with the maximum diameter impeller, and at a given rotative speed. Specific speed is used for many design purposes including efficiency prediction and classifying the relative discharge of an impeller as radial, mixed or axial …

    Get Price
  • Cavitation | Fire Suppression Equipment, Fire Pumps |

    Each pump is designed to operate within a given speed range and under a specific set of intake conditions. Operating a pump at excessive speed or at too high an intake lift, restricting the intake, or any other factor that causes the pressure on the liquid to fall below its vapor pressure produces a condition called cavitation.

    Get Price
  • Centrifiugal Pumps Overview

    2012-2-13 · Centrifugal Pump- Definition • Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. • As the name suggests, it relies on the principal of Centrifugal force. • It converts the energy provided by a prime mover, such as an electric motor, steam turbine, or gasoline engine, to energy

    Get Price
  • Backpack Pumps - National Fire Fighter Corp.

    5 gallon UV resistant poly tank will last for years of heavy use. Rust-free and sturdy. Our brass pump will give years of bind free use. A pump you can count on in an emergency. Comfort features such as padded straps and lumbar support. Lumbar support holds tank away from back and transfers weight from the shoulders to the hips.

    Get Price
  • Pump - definition of pump by The Free Dictionary

    Define pump. pump synonyms, pump pronunciation, pump translation, English dictionary definition of pump. pump1 top: jet pump bottom: centrifugal pump n. 1. A machine or device for raising, compressing, or transferring fluids.

    Get Price
  • pump | meaning of pump in Longman Dictionary of ...

    Related topics: Industry pump pump 2 verb 1 move in a direction [transitive always + adverb/preposition] MOVE something OR somebody to make liquid or gas move in a particular direction, using a pump pump something into/out of/through something The fire department is still pumping floodwater out of the cellars. 2 move from under ground ...

    Get Price
  • Types of pump | Different Types Of Industrial Pumps

    2021-5-16 · Fire hydrant pump systems are also known as fire pumps, & firewater pumps. These pumps are designed to serve water flow with high force and high pressure that can by use by the fireman for firefighting in case of fire in Industry. Pump pipings are connected with a water sump which is dedicated to fire incident only.

    Get Price
  • Fire Apparatus Pump Operations, Mechanics, and Components ...

    2015-3-25 · Fire Apparatus Pump Operations, Mechanics, and Components Plain Water Operations Centrifugal Pumps Fire apparatus pumps use centrifugal force to deliver water to the fireground. Centrifugal force is an outward force associated with rotation. The rotation in a fire apparatus pump …

    Get Price
  • The Jockey Pump, an Important Part of a Fire Pump System.

    2017-10-14 · The Jockey Pump, an Important Part of a Fire Pump System. August 1, 2009 Rev. No. 2 A Jockey Pump is an important component of a fire pump system. The Jockey Pump is not as mundane as many engineers, contractors, and installers would have you believe. Why are they so misunderstood? The Jockey Pump (JP) or Pressure Maintenance Pumps (PMP) as ...

    Get Price
  • Electrical Design for Fire Fighting Pumps ~ Electrical Knowhow

    2018-10-10 · The fire fighting process is done by pumps designed specifically for the system. Initially the jockey pump is used to maintain the pressure and when the fire is confirmed by a sprinklers or by the fire alarm panel the electric pump starts to work and then in case Failure or disconnection of Electricity for Electric Fire Pump The diesel pump is entered into the process.

    Get Price
  • Does 'booster pump' = Fire Pump? - NFPA (fire) Code

    2009-1-9 · The 1998 NFPA 20 definition (1-8): 'Booster Pump. A fire pump that takes suction from a public service main or private use water system for the purpose of increasing the effective water pressure.' I wonder why it was removed. I have found it a fairly common term.

    Get Price
  • Urban Dictionary: Johnny pump

    2021-3-5 · New York City fire hydrants were first installed in 1808, and by 1817 flip lid-style hydrants began to appear on street corners. The term 'johnny pump' is a nickname for fire hydrants that originated in Lower Manhattan and Brooklyn vernacular.

    Get Price
  • Fire Pump Priming Basics - Part 1 | Firehouse

    2007-2-28 · Home; Apparatus; Fire Pump Priming Basics - Part 1. Dominic Colletti discusses fire pump accessories: they may not be glamorous, but priming systems are critical to pump …

    Get Price
  • System Curve and Pump Performance Curve

    2021-5-7 · The System Curve. A fluid flow system is characterized with the System Curve - a graphical presentation of the Energy Equation.. The system head visualized in the System Curve above is a function of elevation - or the static head and the major and minor losses in the system and can be expressed as:. h = dh + h l (1). where

    Get Price