pump head feet

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • What is head? - pumpfundamentals.com

    What is Head feet for pumps? The pump head or discharge head of a water pump is a measure of the power of a pump. This statistic is measured in meters (or feet) and is calculated by placing a tube on a pump's discharge and measuring the maximum height to which it can pump water. Click to see full answer.

    Get Price
  • What is Head feet for pumps? - AskingLot.com

    2008-11-28 · What is Pump Head? Units of Measure: In the U.S. system, head is measured either in PSI or in 'feet of head' (usually abbreviated to 'feet'). Pump Head is the total resistance that a pump must overcome. It consists of the following components: Static Head: Static head represents the net change in height, in feet, that the pump must overcome.

    Get Price
  • Calculating the Pump Head - Amick Racing

    2017-9-6 · Pumps have measurements of “GPM at X feet of Head”. Given the same power and pump design, there is a trade off between Head height and Gallons Per Minute. Typically you will see pump ratings like this: 140 GPM at 40 Feet of Head 100 GPM at 60 Feet of Head 60 GPM at 70 Feet of Head The actual ratings will vary by pump.

    Get Price
  • Pump Head Explained | ieDepot Blog

    2019-5-22 · In terms of pressure the pump head (ΔP pump) is difference between system back pressure and the inlet pressure of the pump. The maximum pump head of a centrifugal pump is mainly determined by the outside diameter of the pump’s impeller and the shaft angular velocity – speed of the rotating shaft. The head will also change as the volumetric flow rate through the …

    Get Price
  • Converting Pump Head to Pressure and Vice Versa

    2016-5-19 · The Result: Total Dynamic Head Calculation. C) Total Dynamic Head: The worst case scenario for the vertical rise is 21 feet. The friction loss for 25GPM is 5.6 feet. Adding these two numbers together, the Total Dynamic Head is 26.6 feet for …

    Get Price
  • Two Key Terms in pump Specifications - GPM and Head

    2021-5-13 · Simply stated: a pump’s head is the maximum height that the pump can achieve pumping against gravity. Intuitively, if a pump can produce more pressure, it can pump water higher and produce a higher head.

    Get Price
  • What is Pump Head – Performance Curve of

    2019-10-15 · A PSI value can be converted to head feet using the following formula: Head = PSI x 2.31/SG The team knows that the pumped fluids have a specific gravity (SG) of 0.8.

    Get Price
  • What is head? - pumpfundamentals.com

    2019-3-16 · Head is a very useful and practical term to use when evaluating a pump's capacity to do a job. Many pump applications involve pumping to a higher level. If you have to pump liquid up 30 ft and your pump doesn't have at least 30 feet of head then there is no chance that your system will work.

    Get Price
  • Understanding the pump head parameters - by ...

    2019-8-15 · feet, rather than in PSIG: A pump performance curve is usually plotted based on its flow rate in gallons per minute (GPM), and its head in Feet. The unit of head is used because a pump will always develop the same head regardless of the specific gravity of the pumped liquid.

    Get Price
  • Calculating the Pump Head - Amick Racing

    2008-11-28 · What is Pump Head? Units of Measure: In the U.S. system, head is measured either in PSI or in 'feet of head' (usually abbreviated to 'feet'). Pump Head is the total resistance that a pump must overcome. It consists of the following components: Static Head: Static head represents the net change in height, in feet, that the pump must overcome.

    Get Price
  • Pump Head Explained | ieDepot Blog

    2015-7-2 · The pump head or discharge head of a water pump is a measure of the power of a pump. The greater the pump head, the greater the pressure that the pump can generate. This statistic is measured in meters (or feet) and is calculated by placing a tube on a pump’s discharge and measuring the maximum height to which it can pump water. What is ...

    Get Price
  • ‘Head’ and ‘pressure’ in pumps | Water Tech Online

    2010-10-13 · Finally, if your system requires 50 feet of head at 600 gpm, then you will want to purchase a pump with best efficiency coordinates of 50 feet at 600 gpm on the pump performance curve. When reading these curves while choosing a pump, there is a certain optimum zone on the pump-curve graph that you want to stay in.

    Get Price
  • Atmospheric Pressure in Feet of Head / Hevvy Pumps

    The relationship between Psi and feet of water head is one of the most basic principals in the pump industry. Having spent the previous few paragraphs discussing one specific example of this relationship, it would seem appropriate at this time to use this example to confirm a well known constant.

    Get Price
  • Pressure To Head Pump Head Calculator -

    Pressure to Head Pump Head Calculator. Converting pressure (psi or bar) to head (ft or m) from imperial or SI units. Pressure in the head calculator.

    Get Price
  • Head | Pump Head and Shut-Off Head Pressure

    2021-5-13 · Learn about Pump Head and Discharge Head Pressure in pumping equipment. Examples, explanations and expert pump advice from Global Pumps, Australia's most trusted industrial pump supplier for mining, government, wine, food, chemical processing, packaging and …

    Get Price
  • Sizing Up a Sump Pump - University of IL

    2008-12-4 · Head of 19.40. Round up to 20 feet. Selecting the Pump You now know your System Capacity (18 gallons per minute) and you know the Total Dynamic Head (20 feet). So you’re ready to select a pump. Most sump pumps have charts or curves that show how many gallons per minute they can pump for different lengths of head (See Figure 2). You’ve ...

    Get Price
  • Pump Picks: How Do You Calculate Pump Size? |

    2014-11-17 · One effluent pump option is the Plus line of high-head turbine pumps from Quanics Inc. The pumps are available in 10, 20 and 30 gpm models, with head capacities of up to 250 feet. Heavy-duty effluent pumps from Ashland Pump are available in multiple horsepower sizes for various performance requirements, and feature efficient permanent split ...

    Get Price
  • Pump Feet of Head and Foot Pounds - BORNQUIST -

    2019-1-2 · The pounds in the numerator and denominator cancel out, leaving feet. This means that the pump will produce the same amount of pump head in feet regardless of the liquid being pumped, assuming relatively similar viscosities. This DOESN’T mean that the pump will require the same pressures in psi.

    Get Price
  • Sump & Sewage Pump Design Calculations: Pump

    2020-3-23 · Pump Head Calculation: Elevation H lift and HD min suction. This is an open system, so elevation in feet that we must lift the water to get into the return main is important. Don’t forget, in a below ground basin, lift (H lift) is from the bottom of the sump and not from the floor level. The minimum suction elevation of a pump is important ...

    Get Price
  • Pump sizing 'feet of head' quandry? - Swimming

    2007-12-21 · The 0.5 HP Hayward pump performance curve shows that at 40 Feet of Head, the pump can flow 60 gallons per minute. The 1 HP Water Ace shows that at 40 Feet of Head, the pump can flow about 67 gallons per minute. Of course these flow rates vary significantly when you assume that there is 30 feet of Head or 50 feet of head.

    Get Price
  • Course Title: Design Considerations For Hydronic Pump ...

    2012-5-29 · PSI = Head (feet) x Specific Gravity 2.31 The pump generates the same head of liquid whatever the density of the liquid being pumped. In the following equation (Bernoulli's equation) each of the terms is a head term: elevation head h, pressure head p and velocity head v 2/2g. Head is equal to specific energy, of

    Get Price
  • Calculating Head Loss in a Pipeline - Pumps & Systems

    2015-4-13 · In Table 4, the head loss drops rapidly as the ID increases. For example, transporting water through a 3.5-inch pipe results in 16.2 feet of head loss, while a 6-inch pipe has a head loss of only 1.1 feet. This reduction in pipeline head loss allows for the selection of a smaller pump that requires less power.

    Get Price
  • Hydraulic Submersible Pump Rentals | Fast Flow Pumps

    Max Vertical Head: 195 Feet. Operating PSI: 2000-3300 PSI. Hydraulic Flow: 4-30 GPM. Type: Hydraulic Submersible Pump. Material: Ductile Iron. Discharge: 4' Male Cam Lock. Dimensions: 22' x 17' x 15' Hydraulic Oil: AW-32 or AW-46

    Get Price
  • What is the difference between pressure and head?

    2016-5-31 · The pump selection of a pump is driven by the following main parameters: – Head (H) – Flow rate (Q) – Fluid characteristics (ρ, γ, T ….) Sometimes head can be confused with pressure during pump choice. As a matter of fact there is a strict relation between them which is defined by the fluid specific gravity, so the relation is fluid dependent.

    Get Price
  • CD103M Dri-Prime® Pump

    2016-6-17 · Head Pump Shaft Impeller Non-return valve body 2200 rpm 2000 rpm 1800 rpm 1600 rpm 1400 rpm 1200 rpm 25% 49% 40% 50% 55% 58% 59% 54% 58% 0 25 50 75 100 125 150 175 200 225 250 0 10 20 30 40 50 60 0 20 40 60 80 100 120 140 160 180 0 100 200 300 400 500 600 700 800 900 1000 1100 Flow (m³/hr) Head (feet) Head (meters) Flow (USGPM)

    Get Price
  • Standard Centrifugal - Pioneer Pump, Inc. - Americas

    Pump: CC PEI CL: FM PEI CL: Size: Max Flow: Max Head: Solids Size: SC315C75: DNP: DNP: 3 x 1.5 inches 80 x 40 mm 120 USgpm 30 m³/h 250 feet 80 metres 0.5 inches 10 mm SC32C75: 1.00: DNP: 3 x 2 inches

    Get Price
  • How to read a pump curve - GemmeCotti

    2015-12-21 · In the example below the pump suitable is magnetic drive centrifugal pump model HTM 31. The curve enables you to see how the pump will perform at any given point within its performance range. For example, the same pump model HTM 31 at 15 m3/h will produce a head of 20 m, or at 24 m of head the pump will generate a flow of 8 m3/h.

    Get Price
  • How to Read a Pump Performance Curve - March Pump

    2014-4-17 · On most pump curves, the Horizontal Axis you see will display flow (and be shown in Gallons in the U.S. and Liters in the rest of the world) and the Vertical Axis you see will display the head put out by the pump (head is given in Feet for the US and Meters for the rest of the world).

    Get Price
  • HVAC Variable Speed Pump Control Head

    2018-6-14 · design and the pump head is 60 feet (Point 1). If the two-way control valve throttles to 400 GPM, the pump moves up its curve and operates at 400 GPM at 80 feet (Point 2). If the valve throttles more and only requires 100 GPM, the pump will produce 90 feet of head (Point 3). We are getting close to shutoff or “0” GPM at 92 feet.

    Get Price
  • Pump Basics - HALL MACH

    2017-9-4 · pump is fed by a reservoir which is at an elevation of 20 feet above the inlet of the pump. The system is located at an elevation of 2,000 feet above sea level. The water is 50 degrees F. The friction loss in the plumbing leading from the tank to the pump inlet is calculated at 3 feet of head. NPSHR, NPSHA, & CAVITATION An Example

    Get Price
  • What is the difference between pressure and head?

    2016-5-31 · The pump selection of a pump is driven by the following main parameters: – Head (H) – Flow rate (Q) – Fluid characteristics (ρ, γ, T ….) Sometimes head can be confused with pressure during pump choice. As a matter of fact there is a strict relation between them which is defined by the fluid specific gravity, so the relation is fluid dependent.

    Get Price
  • Rules to Follow to Avoid Pump Problems | Valin

    2014-8-5 · Where does the 2.31 come from? Divide 33.9 feet of head by 14.7 psia. Water has a specific gravity of 1.0. So the formula always works. If the specific gravity is known for the fluid that is being pumped, pressure gauge readings can be converted to Head in Feet, which is useful for determining where the centrifugal pump is operating on its pump curve.

    Get Price
  • How to Calculate Water Pump Horsepower: 14 Steps

    2021-3-21 · The water horsepower, or minimum power required to run the pump, equals , where TDH is the total dynamic head in feet, Q is the flow rate in gpm, and SG is the specific gravity (1 for water). Enter all the values you found into this formula to find the water horsepower for your project.

    Get Price
  • Hydraulic Submersible Pump Rentals | Fast Flow Pumps

    Max Vertical Head: 195 Feet. Operating PSI: 2000-3300 PSI. Hydraulic Flow: 4-30 GPM. Type: Hydraulic Submersible Pump. Material: Ductile Iron. Discharge: 4' Male Cam Lock. Dimensions: 22' x 17' x 15' Hydraulic Oil: AW-32 or AW-46

    Get Price
  • NPSH Calculation: A Step-by-Step Guide - Pumps &

    2018-7-11 · Now you just need to convert the atmospheric pressure from psia to feet of head. Multiply 14.7 by 2.31, and the result is 33.957 feet, rounding to 34 feet. The value for the first component in the equation is 34 feet. We will cover the effects of higher elevations and vacuum in later articles.

    Get Price
  • Standard Centrifugal - Pioneer Pump, Inc. - Americas

    Pump: CC PEI CL: FM PEI CL: Size: Max Flow: Max Head: Solids Size: SC315C75: DNP: DNP: 3 x 1.5 inches 80 x 40 mm 120 USgpm 30 m³/h 250 feet 80 metres 0.5 inches 10 mm SC32C75: 1.00: DNP: 3 …

    Get Price
  • Self-Priming - Pioneer Pump, Inc. - Americas

    Ideal for lift stations, municipal sewer or industrial wastewater needs, the Pioneer Pump® GS Series is a cost-effective solution for high head applications with high performance demands. These robust self-priming sewage pumps are available in 3, 4, 6, 8, and 10-inch sizes, with maximum flow rates up to 3,450 gpm, a maximum head of 175 feet ...

    Get Price