    Head Height Calculator. This Head Height Calculator will help you determine your Total Dynamic Head (TDH) and knowing your (TDH) will give you the correct flow rate you will need from a pond pump in order to produce the flow rate you desire. When choosing a pump, you may already know how many litres per minute you require.

    Get Price
  • Pressure To Head Pump Head Calculator -

    Head (m) Pressure (bar) Head (m) 1: 10,20: 26: 265,20: 2: 20,40: 27: 275,40: 3: 30,60: 28: 285,60: 4: 40,80: 29: 295,80: 5: 51,00: 30: 306,00: 6: 61,20: 31: 316,20: 7: 71,40: 32: 326,40: 8: 81,60: 33: 336,60: 9: 91,80: 34: 346,80: 10: 102,00: 35: 357,00: 11: 112,20: 36: 367,20: 12: 122,40: 37: 377,40: 13: 132,60: 38: 387,60: 14: …

    Get Price
  • Pump Calculator - Pentair Aquatic Eco-Systems

    Enter the total horizontal pipe length (feet) for your system. Select nominal pipe diameter (inches) using the pull-down menu. Enter total pumping lift or height (feet) water is pumped vertically. Enter any misc. head loss (filters, heater, chiller, skimmer, UV, etc.). Enter the number of pipe fittings (elbows, tees). .

    Get Price
  • Calculating the Pump Head - Amick Racing

    2008-11-28 · added to the pump for this item? Answer: Feet in Head = 8.5 PSI X 2.31ft./PSI = 19.64 ft. Step 4: Determine the Static Head (Open Systems Only) The static head is simply the total height that the pump must lift the fluid. It applies only in open systems. Remember that the static head is the difference in height that the pump …

    Get Price
  • How to Calculate Total Head - Strongman Pumps

    2019-6-10 · height of water above the pump suction or intake. Discharge static head is the height of water above the pump discharge. Total static head is the difference between these two, this is the head that the pump will have to produce to at least get the water up to the high point. Figure 7 Suction, discharge and total static head. The total static head …

    Get Price
  • Pump Power Calculator - Engineering ToolBox

    Head: Pressure: metres: feet: bar: psi: 0.50: 1.64: 0.05: 0.71: 1.00: 3.28: 0.10: 1.42: 1.50: 4.92: 0.15: 2.14: 2.00: 6.56: 0.20: 2.85: 5.00: 16.40: 0.49: 7.12: 10.00: 32.81: 0.98: 14.24: 15.00: 49.21: 1.47: 21.36: 20.00: 65.62: 1.96: 28.48: 30.00: 98.43: 2.94: 42.72: 40.00: 131.23: 3.92: 56.96: 50.00: 164.04: 4.91: 71.19: 100.00: 328.08: …

    Get Price
  • Pump and piping sizing

    2017-10-14 · With 4 feet of head, max head height is not a concern if you buy a decent pump big enough and figure in loss. Can’t think of any decent pumps in the gph range you should be looking at that don’t max out at 10-12 feet, so you’re well with in range where that need not be a concern Last edited: Oct 13, 2017 Oct 13, …

    Get Price
  • Pump Head Calculator - Online Calculator -

    Pump Head Calculator, Use the Form Below to Calculate the Pump Head in SI unit or Imperial Units (Field units). Total head with flow

    Get Price
  • Pump head heights - Pond Supplies

    2021-5-12 · Maximum pumping height (total head) For vertical lift. For a given pump, the higher water is pumped vertically - the lower the flow; at a given height the flow will be zero. The terms 'head height' or 'lift' are used to indicate this vertical height, measuring how high the water can be pumped for a particular application.

    Get Price
  • Calculating the Pump Head - Amick Racing

    2008-11-28 · The static head is simply the total height that the pump must lift the fluid. It applies only in open systems. Remember that the static head is the difference in height that the pump will be required to provide. In the drawing below, showing a cooling tower, the static height might appear to be 40’. ...

    Get Price
  • Pump Power Calculator - Engineering ToolBox

    2021-5-7 · Hydraulic Pump Power. The ideal hydraulic power to drive a pump depends on. the mass flow rate the; liquid density; the differential height - either it is the static lift from one height to an other or the total head loss component of the system - and can be calculated like. P h(kW) = q ρ g h (3.6 10 6) = q p (3.6 10 …

    Get Price
  • Net Positive Suction Head Available (NPSHa)

    NPSHA Pump Calculator. This net positive suction head available (NPSHA) calculator provides the amount of available head for a pump. This head measurement is also referred to as the liquid pressure at the pump suction. Every pump requires a certain amount of net positive suction head, which is referred to as NPSHr.

    Get Price
  • What Size Pond Pump Do I Need? (Pump

    2019-1-6 · For example, if your fountain’s head height is 22 inches and its outlet diameter is 3 inches, you’ll want a pump that provides least 300 GPH (3 * 100 = 300 GPH) and has a max head height of about 33 to 35 inches (22 * 1.5 = 33). Waterfall Pump Calculator & Guidance:

    Get Price
  • Pump Head Calculation In high rise - HVAC/R

    2014-10-23 · When you first fill the system in a high rise, you have to do it with a pump that can overcome the height head loss. If it’s a 300 ft tall building for example you need a pump with at least 300 ft head. The system’s pump that is designed for 600 gpm pump at 100 ft head won’t do much good until the loop is filled.

    Get Price
  • Sump Pump Sizing Calculator - How to Easily Size

    2021-5-8 · Sump Pump Sizing Calculator - Easily Calculate a Primary Sump Pump. Whether you are replacing an old sump pump or buying a new primary or backup pump, this simple sizing guide will get you the right GPM and Horsepower quickly. Sump Pumps Direct makes buying sump pumps and accessories easy.

    Get Price
  • Sizing Up a Sump Pump - University of IL

    2008-12-4 · Determine Static Head Total Dynamic Head is equal to Static Head (or “vertical lift”) plus Friction Head. Static Head is the vertical height that the water rises through the discharge pipe. Begin measuring from the point where water enters the sump pump. Then measure up vertically to where the pipe becomes horizontal …

    Get Price
  • Suction Lift Calculator - Pump and Valve

    Since commencing operation in the 1970’s, Pump & Valve has been dedicated to providing solutions in all fields of fluid handling. We supply pumps, valves, packaged pump stations, oil/water separators and storm water treatment devices to all major industries in New Zealand and the pacific islands.

    Get Price
  • Pump Power Calculator - Engineering ToolBox

    2021-5-7 · Hydraulic Pump Power. The ideal hydraulic power to drive a pump depends on. the mass flow rate the; liquid density; the differential height - either it is the static lift from one height to an other or the total head loss component of the system - and can be calculated like. P h(kW) = q ρ g h (3.6 10 6) = q p (3.6 10 …

    Get Price
  • How to size a Circulator Pump. Taco pump curves.

    Height (#10 on the Scheme above) is not taken into consideration. Given real conditions, we may add extra 2 ft of head just in case, making pressure drop 11ft of head. The next and final step, is to match the obtained data with a correct pump on a Circulator Pump Curve Chart (see below).

    Get Price
  • QUICK GUIDE FOR PUMP SELECTION

    2017-11-3 · TO CHOOSE A PUMP WE NEED TO KNOW 2 BASIC VALUES: FLOWRATE AND LIFT PRESSURE OR HEIGHT (OR HEAD) the quantity of liquid (water) flowing trough the pipe in a certain timespan. THE MOST COMMON MEASUREMENT UNITS: • m3/h • 1litre/s = 3,6 m3/h • 1 litre/min = 0,06 m3/h A: …

    Get Price
  • Net Positive Suction Head Available (NPSHa)

    NPSHA Pump Calculator. This net positive suction head available (NPSHA) calculator provides the amount of available head for a pump. This head measurement is also referred to as the liquid pressure at the pump suction. Every pump requires a certain amount of net positive suction head, which is referred to …

    Get Price
  • How to Size a Sump Pump - Sump Pump Sizing

    Sump Pump Sizing Chart. Use our sizing chart to help pick the right pump if you already know information like head height and max gallons per hour. Sump Pump Sizing Calculator. If you know your head height, discharge pipe distance or gallons per hour you can use our calculator to pick to right horsepower motor.

    Get Price
  • Hayward Hydraulics and Pump Sizing For Existing Pools

    2017-11-7 · to the front of the pump is an ideal place to attach the vacuum gauge. Take the vacuum reading of the pump and multiply the value by 1.13. This is the amount of Friction Loss for the suction side of the system. Example 4 19 inches of mercury x 1.13 = 21.47 ft. of water. Page 10

    Get Price
  • Fountain pump tutorial

    2019-2-16 · The total head of the pump H P will be the sum of the static head H S, the pipe friction head H F and the nozzle head H N. H P = H S + H F + H N. In this case, the static head is zero or is so small that it is close enough to zero. The static head is the difference in height between the fluid particles located at the inlet of …

    Get Price
  • Waterfall Pump Calculator - Pondkeeper

    Waterfall Pump Calculator. Enter your details. The height difference between the surface of the water and the top of the water fall (in metres) The width of the water pour (in cm) Calculate . Results. Recommended pumps size (lph) Need some help? From building your own pond to calculating what you need, we can help. ...

    Get Price
  • Centrifugal Pumps- Part III- Shutoff Pressure

    2018-8-29 · Rated head of the pump is also clear. Plant designer knows the rated head of the pump. According to clause 6.1.11 of API 610,11th Ed., the minimum head rise from rated point to shutoff head shall ...

    Get Price
  • Slurry Pump Calculations - Slurry Pumping and

    The available value depends on the ambient air pressure (height above sea level), the vapor pressure of the liquid, the density of the slurry, and the level in the sump. Example: Pumping a water-based slurry at a height of 1000 m above sea level. Liquid temperature 40°C, liquid level 2 meters above the pump inlet. Formula:

    Get Price
  • Pump Head Calculation - Pump Performance

    2021-5-8 · In fluids dynamics the term pump head is used to measure the kinetic energy which a pump creates. Head is a measurement of the height of the incompressible fluid column the pump could create from the kinetic energy, that the pump gives to the liquid. The head and flow rate determine the performance of a pump, which is graphically shown in the figure as the performance curve or pump …

    Get Price
  • Pump Sizing Calculation

    2019-7-28 · Pump Sizing does the hydraulic calculation for a centrifugal pump and estimates differential head, hydraulic power, motor power, NPSH available.

    Get Price
  • Pump Suction Head and Altitude - Engineering

    2021-5-7 · Pressure to Head - Unit Converter - Convert between pressure and head units - like lb/in 2, atm, inches mercury, bars, Pa and more .. Pumps - Suction Specific Speed - Suction Specific Speed can be used to determine stable and reliable operations for pumps with max efficiency without cavitation

    Get Price
  • How to find pump size and pump head calculation

    2015-6-11 · The NPSHr is given by the pump manufacturer and is often shown on the pump curve. Net positive suction head available = absolute pressure head at the pump suction – liquid vapour pressure head. Pump Power Pumps are usually driven by electric motors, diesel engines or steam turbines.

    Get Price
  • Pump Operation Series Parallel - CheCalc

    2020-1-4 · Pump in Parallel. With pumps in parallel, the flow rates are additive with a common head. The flowrate Qt is split between the inlet into Q1 and Q2. Each pump develops the same head H at the corresponding capacity. Thus, the first pump at capacity Q1 develops the same head H as the second pump at capacity Q2.

    Get Price
  • Condenser Water Pump Calculator - FINAL

    2018-9-6 · Water Pump calculator to be able to use the calculator and to fill out a condenser water pump schedule. This guide covers the overall condenser water system, the calculator and the ... primary purpose of the calculator is to find the total dynamic head and net positive suction head available for use in the Condenser Water Pump …

    Get Price
  • Common Pump Formula - Home - M.G. Newell

    2016-5-23 · P = Pressure head (psi) where: h = height of fluid (ft) SG = specific gravity Total Head H = H t – (±H s) where: H t = total discharge head H s = total suction head Total Discharge Head H t = h t + h ft + p t where: h t = static discharge head h ft = pressure drop in discharge line p t > 0 for pressure p t < 0 for vacuum …

    Get Price
  • Pump Power Calculator, Formula, Example,

    2021-5-15 · Pump Power calculator: Enter the flow, fluid density (available at the bottom), gravity, head and pump efficiency. Then press the calculate button to get the pump power, motor power. Also, you can change the power unit from kW to HP. By default, we have included the 10m head water pump for the flow of 50 […]

    Get Price
  • Pump Picks: How Do You Calculate Pump Size? |

    2014-11-17 · One effluent pump option is the Plus line of high-head turbine pumps from Quanics Inc. The pumps are available in 10, 20 and 30 gpm models, with head capacities of up to 250 feet. Heavy-duty effluent pumps from Ashland Pump are available in multiple horsepower sizes for various performance requirements, and …

    Get Price
  • How to Size a Fountain Pump | Hunker

    2018-11-19 · This is the head height rating. The head height rating is the measurement needed to know how high the pump needs to be to push the water in order for it to reach the spout and release the water into the waterfall, rock feature or basin. The pumping height is the space between the outlet port on the pump to …

    Get Price
  • Pump Sizing Calculation

    2019-7-28 · Pump Sizing does the hydraulic calculation for a centrifugal pump and estimates differential head, hydraulic power, motor power, NPSH available.

    Get Price
  • Pump Head Calculation - Pump Performance

    2021-5-8 · In fluids dynamics the term pump head is used to measure the kinetic energy which a pump creates. Head is a measurement of the height of the incompressible fluid column the pump could create from the kinetic energy, that the pump gives to the liquid. The head and flow rate determine the performance of a pump, which is graphically shown in the figure as the performance curve or pump ...

    Get Price
  • Pump Suction Head and Altitude - Engineering

    2021-5-7 · Pressure to Head - Unit Converter - Convert between pressure and head units - like lb/in 2, atm, inches mercury, bars, Pa and more .. Pumps - Suction Specific Speed - Suction Specific Speed can be used to determine stable and reliable operations for pumps with max efficiency without cavitation

    Get Price
  • Converting Pump Head to Pressure and Vice Versa

    2021-5-7 · Example - Converting Pump Head - feet - to Pressure - psi. The pressure - psi - of a water pump operating with head 120 ft can be calculated with eq. 1 as: p = 0.433 (120 ft) (1) = 52 psi. Example - Converting Pressure - psi - to Pump Head - feet. The head in feet water column can be calculated from …

    Get Price
  • How to find pump size and pump head calculation

    2015-6-11 · The NPSHr is given by the pump manufacturer and is often shown on the pump curve. Net positive suction head available = absolute pressure head at the pump suction – liquid vapour pressure head. Pump Power Pumps are usually driven by electric motors, diesel engines or steam turbines.

    Get Price
  • Pump Operation Series Parallel - CheCalc

    2020-1-4 · Pump in Parallel. With pumps in parallel, the flow rates are additive with a common head. The flowrate Qt is split between the inlet into Q1 and Q2. Each pump develops the same head H at the corresponding capacity. Thus, the first pump at capacity Q1 develops the same head H as the second pump at …

    Get Price
  • Common Pump Formula - Home - M.G. Newell

    2016-5-23 · P = Pressure head (psi) where: h = height of fluid (ft) SG = specific gravity Total Head H = H t – (±H s) where: H t = total discharge head H s = total suction head Total Discharge Head H t = h t + h ft + p t where: h t = static discharge head h ft = pressure drop in discharge line p t > 0 for pressure p t < 0 for …

    Get Price
  • Back to Basics Pump Sizing - AIChE

    2016-12-2 · The static head is created by any vertical columns of liquid attached to the pump and any pressurized systems attached to the pump outlet. The static head exists under static conditions, with the pump switched off, and does 3 not change based on flow. The height of fluid above the pump’s centerline can be …

    Get Price
  • Pump Picks: How Do You Calculate Pump Size? |

    2014-11-17 · One effluent pump option is the Plus line of high-head turbine pumps from Quanics Inc. The pumps are available in 10, 20 and 30 gpm models, with head capacities of up to 250 feet. Heavy-duty effluent pumps from Ashland Pump are available in multiple horsepower sizes for various performance requirements, …

    Get Price
  • Centrifugal Pumps & Fluid Flow Practical Calculations

    2018-7-18 · Since the volume is equal to the cross-sectional area (A) multiplied by the height (h) of liquid, then: P = ρ.h.g g c Example 1: If the tank in figure above is filled with water that has a density of 62.4 lbm/ft³, calculate the pressures at depths of 10, 20, and 30 feet. Solution: P = ρ.h.g gc